rs
|
|
|
|
|
Specification |
|
Rated Voltage |
415V, 3PH. Wire,50 / 60 Hz |
Rated Current |
3A, 6A ,15A & 30A |
Test Voltage |
1500v ac between Main terminals Shorted together & earth for 60 Secs. |
Insulation Resistance |
> 100 m ohm between mains terminals shorted together & earth at 500 V DC |
Leakage Current |
2 mA max at 415 V, 50Hz |
Voltage Drop |
1 V rms Max |
Operating Temperature Range |
0 to 85 Celsius
|
Surge Suppressor |
Clamping Voltage 715 V Response Time 100n Sec. |
Insertion Loss |
Current Ratings AMPS |
|
3 |
6 |
15 |
30 |
|
Common Mode Insertion Loss
(dB in a 50 ohm system)
FREQUENCY-MHz |
0.15 |
>25 |
>15 |
>8 |
>5 |
|
0.5 |
>30 |
>20 |
>12 |
>10 |
|
1.0 |
>35 |
>30 |
>20 |
>18 |
|
5.0 |
>40 |
>35 |
>30 |
>28 |
|
10 |
>45 |
>40 |
>35 |
>40 |
|
30 |
>50 |
>45 |
>40 |
>35 |
|
Mechanical Diagram |
All Dimensions In MM |
|
|
|
|
|
|
|
|
RF I/ EMI Filters For AC Drives ( Input Filter Sak-Drv & Output Filter Sak-Dro) |
|
|
|
Specification |
|
Voltage |
440Vac, 50Hz,3 wire System |
Leakage Current |
3mA@440V ac, 13mA@2500V ac for 1 minute |
Insulation |
500 V DC, 500M ohm, (Line to earth for 1 Sec) |
Resistance |
> 100 m ohm between mains terminals shorted together & earth for 60 Sec's |
Break down Voltage |
2500V ac -Line to earth for 1 min. |
Overload Capacity |
150 % for 1 min Max |
Humidity |
95% |
Temp |
55 C |
Attenuation for Input Filter |
Mhz |
o.1 |
1 |
10 |
100 |
ab |
>20 |
>40 |
>40 |
>20 |
|
|
OUTPUT FILTERS |
INPUT FILTERS |
Drive |
Filter Rating |
Models |
Drive |
Filter Rating |
Models |
5 Hp |
15 AMP |
SAK-DRO-10 / 04 |
1 Hp |
5 AMP |
SAK-DRV-5 / 04 |
7.5 Hp |
20 AMP |
SAK-DRO-20 / 04 |
3 Hp |
10 AMP |
SAK-DRV-10 / 04 |
15 Hp |
30 AMP |
SAK-DRO-30 / 04 |
5 Hp |
15 AMP |
SAK-DRV-15 / 04 |
25 Hp |
45 AMP |
SAK-DRO-45 / 04 |
7.5 Hp |
20 AMP |
SAK-DRV-20 / 04 |
30 Hp |
75 AMP |
SAK-DRO-75 / 04 |
10 Hp |
30 AMP |
SAK-DRV-30 / 04 |
|
20 Hp |
40 AMP |
SAK-DRV-20 / 04*2# |
25 Hp |
60 AMP |
SAK-DRV-30 / 04*2# |
30 Hp |
90 AMP |
SAK-DRV-30 / 04*3# |
40 Hp |
120 AMP |
SAK-DRV-30 / 04*4# |
|
|
|
|
|
|
Power Line Filters for single phase AC Drives |
|
|
|
|
|
|
Specification |
|
Rated Voltage |
230V, 50HZ ( 440V,50Hz On request.) |
Rated Current |
6A, 10A & 15A |
Test Voltage |
1500v ac between Main terminals Shorted together & earth for 60 Secs. |
Insulation Resistance |
> 20 m ohm between mains terminals shorted together & earth at 500 VDC |
Leakage Current |
2 * 0.2 mA max at 230V, 50Hz |
Voltage Drop |
1 V rms Max |
Operating Temperature Range |
55 c |
Insertion Loss |
Current Ratings AMPS |
|
3 |
6 |
10 |
|
Common Mode Insertion Loss
(dB in a 50 ohm system)
FREQUENCY-MHz |
0.15 |
>15 |
>10 |
>8 |
|
0.5 |
>25 |
>20 |
>15 |
|
1.0 |
>30 |
>25 |
>20 |
|
5.0 |
>45 |
>40 |
>35 |
|
10 |
>50 |
>50 |
>45 |
|
30 |
>55 |
>50 |
>45 |
|
Circuit Diagram |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Copyright © 2007 Madhu Subtronic Components Pvt. Ltd. All rights reserved. |